Cart Total: $0
View Cart | Checkout
    https://installationpartssupply.com/mm5/merchant.mvc?

Home > WATTS PRODUCTS > ASSE 1022 Backflow Double Check Vented | Watts SD2


ASSE 1022 APPROVED, LEAD FREE


1/4"x1/4" Flare x FPT Dual Check, Vented w/ Strainer ASSE 1022 Watts 0061653

 

1/4 Quantity in Basket: None
Code: SD3-MF-4B
Price: $59.17
Description: 1/4"x1/4" Flare x FPT Dual Check, Vented w/ Strainer ASSE 1022 Watts 0061653
1/4" Flare x FPT Dual Check Vented ASSE 1022
w/ Strainer Watts 0061653
In Stock
 
 
Quantity:
 
Click here for Product Info and Installation Instructions
THESE VENT ATMOSPHERICALLY, MEANING WATER WILL LEAK FROM THE VENT PORT!
Some leak more than others. Installers must use their Fitting and Tubing of choice to run to a floor drain or drain saddle, see related items below the table.
This will satisfy the bureaucrat that is stopping you from making coffee & beverage.
Failure to read and follow the installation instructions, is a failure!
Click here for Product Info and Installation Instructions
Watts Series 3/8 SD3-MF, SD3-LS-MFxMF is a dual check with atmospheric port designed for the protection of the water supply from carbon dioxide gas and carbonated water. These substances can flow from post-mix beverage systems and are very acidic. If the acidic water comes in contact with copper tubing or copper pipe, it will cause the leaching of copper salts into the water supply. The dissolved copper if ingested can cause nausea, abdominal pain, and in some cases vomiting.

The Watts Series 3/8 SD3-MF, SD3-LS-MFxMF prevents the reverse flow of potentially contaminated water into the potable water supply. The Watts Series 3/8 SD3-MF, SD3-LS-MFxMF atmospheric vent provides a visual indication of failure in the event that the downstream check fails and system back-pressure exceeds the supply pressure.

Watts Series 3/8 SD3-MF, SD3-LS-MFxMF is recommended for use on Post-Mix Carbonated Beverage Equipment and equipment for tea and coffee.

Installation InstructionBefore installing, flush out pipe lines to removescale and other foreign matter. The valve can beinstalled horizontally or vertically (flow up or down).Install the valve in the line with the arrow on thevalve body pointing in the direction of flow.Connect a vent discharge line to the vent outlet ofthe Watts Series 3/8 SD3-MF, SD3-LS-MFxMF and vent to a safe place of disposal withadequate ventilation. The valve should be installedsuch that the strainer and the valve are accessiblefor service and maintenance.

 
IPS is Closed for Business Thanksgiving Week
ips247.com takes orders 24/7 and will be processed in the order received for immediate shipping
Follow Installation Parts Supply.com® on:

Terms & Conditions | Privacy Policy | Email | Contact IPS
Pumps | Water Filters | Pressure Regulators | Backflow Preventers | Carbonators | Cold Plates | Dispensers
Taprite CO2 Regulators | Oetiker Clamps | Tubing & Hose | Brass Fittings | Stainless Fittings | John Guest Fittings
Bottle Water Pumps | Beer Equipment | Electrical Hardware

TOP OF PAGE | HOME | Google

© 2016 INSTALLATION PARTS SUPPLY® All Rights Reserved.
ALL COPYRIGHTS AND TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE COMPANY(S).
IPS claims no ownership or rights of listed Logo's, Names or Products other than; IPS, its Company Logo, and INSTALLATIONPARTSSUPPLY.COM®.

Warning: Some Products listed on www.installationpartssupply,com can expose you to chemicals, including lead, which are known to the state of California to cause cancer and birth defects or other reproductive harm. For more information visit www.P65Warnings.ca.gov.
Some of the products, may or may not meet AB1953 for lead content.
It is the customers/buyers and ultimately the user/installers responsibility to be aware of and know all laws pertaining to the use of specific products such as Backflow Preventers
IPS is a distributor, not a manufacturer and IPS-Installation Parts Supply.com and its principles shall be held harmless of any and all damages including but not limited to:
legal action for misuse, physical, property, water damage or otherwise for any reason. Purchaser/user/installer claims, bears and holds all responsibility.
Some Images are for illustration only and are subject to change according to current inventory and/or Factory Production. Prices subject to change with market fluctuation.
With purchase, The Customer agrees to all terms and conditions as outlined here and on IPS247.com® Terms and Conditions.

Credit Cards
PCI Compliance


*Local Will Call Hours: 9:00am - 3:00pm Pacific
*DUE TO INSURANCE PURPOSES, LOCAL WILL CALL ORDERS MUST BE PLACED VIA THE WEBSITE.
We will pull your order and have it ready for you to pick-up within Will Call hours.
Please allow at least 1 (one) hour to process your order after it has been placed prior to will call.
(Select "Local Will Call" when prompted to choose a Shipping Method; Email IPS if this option is not available)
All Will Calls/Pick Ups and Deliveries are at the "Man Door" on Side of Building @ Shipping Department.
Switch to Mobile