     HOME > REVERSE OSMOSIS | R.O. > Purotwist R.O. | Q-Series

Purotwist R.O. | Q-Series


Reverse Osmosis Systems, PT4000 4 Stage, Omnipure Q-Series Filters

PICTORIAL LANDING PAGE; Make your selection by clicking an image button below, Or Use The Sidebar Menu.See below for an Instructional Video on how to Service and Replace your PuroTwist Filtration System
PT4000 Q-Series Reverse Osmosis System Q-Series Water Filters for Purotwist Reverse Osmosis System
The Purotwist RO System conforms to NSF/ANSI Standards 58 for performance claims as verified and sustained by test data. All pre and post filtration demands were removed prior to contaminant reduction performance testing by the Water Quality Association laboratory.
The Purotwist reverse osmosis drinking water system is designed for easy installation and maintenance. Please note that routine maintenance is essential to the longevity and performance of RO systems. Filters should be changed every six months depending on the quality of the feed water supply. The Purotwist RO installation should comply with all state and local laws and regulations. Manufacturer recommends a TDS test every six months. This system is acceptable for treatment of influent concentrations of no more that 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 40 psig or greater. This reverse osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant reduction performance.
    PuROTwist Gold series Features:
  • Stage 1 5 Micron Sediment Filter; Removes dirt, sediments, sand, and other physical particles.
  • Stage 2 Pre Carbon Filter: Provides protection to the RO membrane from free chlorine and sediment.
  • Stage 3 Reverse Osmosis Membrane: Membrane reduces a high percentage of dissolved inorganics.
  • Stage 4 Post Carbon Filter: A final polishing process that enhances and clarifies your drinking water.
  • Contaminant Reduction: TDS, Barium, Cadmium, Hexavalent and Trivalent, Chromium, Lead, Copper, Radium 226/228, Selenium, Fluoride, Nitrate/Nitrite
  • Efficiency Rate; 12.1 %
  • Recovery Rate; 21 %
  • Daily Production Rate; 17 gpd
  • Test parameters: 25º± 1ºC, 50 psi and pH of 7.5
  • WQA Gold Seal Certified to NSF Standard 58
  • NSF/Prop 65 lead free air gap faucet
  • Auto shut off valve
  • Tank ball valve
  • Feed supply
  • 3/8" From tank to faucet for full flow
  • Omnipure filters
  • John Guest fittings
  • Drain connector
  • Log In For Your Wholesale / Volume Price or Contact IPS For Volume Quotes & Other Options Click Here! sales@ips247.com
  • 3-5 Day ETA for Out of Stock/Non-Stock Items in this Category
Follow Installation Parts Supply.com® on:

Terms & Conditions | Privacy Policy | Email | Contact IPS
Pumps | Water Filters | Pressure Regulators | Backflow Preventers | Carbonators | Cold Plates | Dispensers
Taprite CO2 Regulators | Oetiker Clamps | Tubing & Hose | Brass Fittings | Stainless Fittings | John Guest Fittings
Bottle Water Pumps | Beer Equipment | Electrical Hardware

TOP OF PAGE | HOME | Google

© 2016 INSTALLATION PARTS SUPPLY® All Rights Reserved.
ALL COPYRIGHTS AND TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE COMPANY(S).
IPS claims no ownership or rights of listed Logo's, Names or Products other than; IPS, its Company Logo, and INSTALLATIONPARTSSUPPLY.COM®.


Some of the products listed on InstallationPartsSupply.com® may contain chemicals
known to the State of California, Vermont and other states to cause cancer, birth defects or other reproductive harm.
Some of the products, may or may not meet AB1953 for lead content.
It is the customers/buyers and ultimately the user/installers responsibility to be aware of and know all laws pertaining to the use of specific products such as Backflow Preventers
IPS is a distributor, not a manufacturer and IPS-Installation Parts Supply.com and its principles shall be held harmless of any and all damages including but not limited to:
legal action for misuse, physical, property, water damage or otherwise for any reason. Purchaser/user/installer claims, bears and holds all responsibility.
Some Images are for illustration only and are subject to change according to current inventory and/or Factory Production. Prices subject to change with market fluctuation.
With purchase, The Customer agrees to all terms and conditions as outlined here and on IPS247.com® Terms and Conditions.


Credit Cards
PCI Compliance


*Local Will Call Hours: 9:00am - 3:00pm Pacific
*DUE TO INSURANCE PURPOSES, LOCAL WILL CALL ORDERS MUST BE PLACED VIA THE WEBSITE.
We will pull your order and have it ready for you to pick-up within Will Call hours.
Please allow at least 1 (one) hour to process your order after it has been placed prior to will call.
(Select "Local Will Call" when prompted to choose a Shipping Method; Email IPS if this option is not available)
All Will Calls/Pick Ups and Deliveries are at the "Man Door" on Side of Building @ Shipping Department.
Switch to Mobile